A
Dial Tone is not returned from
distant office.
In case of COT card
In case of ODT card
B
CHAPTER 2 TROUBLESHOOTING
FAULT DIAGNOSIS AND TROUBLESHOOTING
(1)
Disconnect the trunk from the line
CHECK
on the MDF.
(2)
Connect a test telephone set to the
C.O. line (distant office side) on the
MDF.
SW
TRUNK
(3)
If Dial Tone is returned by going
off-hook on the test telephone set,
check for trouble with wiring on the
MDF and the trunk card.
(4)
If not, there is a problem with the
distant office or the C.O. line.
REPLACE
(1)
Trunk card.
(1)
Disconnect the trunk from the line
CHECK
on the MDF.
(2)
To perform a Loopback Test, make
a back to back connection of the
trunk card and another trunk within
the system at the MDF.
NOTE:
– 213 –
MDF
To Distant Office
Test Telephone Set
This test only works when the
trunks are assigned for type V
operation.