NEC NEAX 2000 IPS Maintenance Manual page 210

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

CARD NAME
PN-2ILCA (ILC)
ACT0-1 lamp is
not on
PAL0-1 lamp is
on
B10/B11/B20/
B21 lamp is
Flashing (60 IPM)
PN-8IPLA
RUN lamp is not
(IP-PAD)
flashing
L0 lamp is on
LINK lamp is not
on
Remedial Action on Each Lamp Status
LAMP
FAULT
STATUS
CONTENT
Abnormal opera-
tion of No.0-1 cir-
cuit
No.0-1 Line is
short-circuiting
Programming is
not set up
Abnormal opera-
tion of IP-PAD
card
LAN connection
failure
LAN connection
failure
CHAPTER 2 TROUBLESHOOTING
FAULT DIAGNOSIS AND TROUBLESHOOTING
REMEDIAL ACTION
Confirm the programming data:
1
CM06, CM10/CM14, CMAC.
Reset the system (Push the SW1 of
2
MP).
Check to see if the Terminal Adapter is
correctly connected and the power is on.
Confirm the programming data:
1
CM06, CM10/CM14, CMAC.
Reset the system (Push the SW1 of
2
MP).
Confirm the programming data:
1
CM0A.
Reset the MB switch.
2
(Down Up Down)
If the fault cannot be cleared,
3
replace the card.
Check to see if the LAN cable is cor-
rectly connected.
Check to see if the LAN cable is
1
correctly connected.
Confirm the condition of the LAN
2
device (such as power of the HUB)
connected to the IP-PAD.
If the fault cannot be cleared,
3
replace the card.
– 200 –
Continued on next page
NWA-008847-001 Rev.3.0