NEC NEAX 2000 IPS Maintenance Manual page 91

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

(7)
Command output is interrupted if you press "Esc" key while command output is being executed.
When operating from MATWorX, you can interrupt by pressing "Stop MP-FP command print out"
on the Trace screen.
(8)
When system initialization is executed in online mode (SW3 of MP card is set to 0), the command
output setting (CMF6 Y=2>03) is cleared and command output is stopped.
(9)
All settings assigned by CMF6 Y=2 are initialized if you input CCC for CMF6 Y=2>03.
(10) Output commands can be defined by "Command code", "FP number", and "Specification of
particular data". AND/OR conditions when combining command code (CMF6 Y=2>00, 10, 11, 12),
FP numbers (CMF6 Y=2>01, 20, 21, 22), and specified data (CMF6 Y=2>30, 31, 32, 33) are the
following.
OR : Command is output when a specified condition matches either of two conditions
AND: Command is output when a specified condition matches both of two conditions
00
00
10
11
12
01
20
21
22
30
31
32
33
CMF6 Y=2 first data
10
11
12
01
OR
OR
OR AND AND AND AND AND
OR
OR AND AND AND AND
OR AND AND AND AND
AND AND AND AND
CHAPTER 1 MAINTENANCE SERVICE FEATURES
20
21
22
OR
OR
OR
OR
OR
OR
– 81 –
ONLINE MP-FP COMMAND OUTPUT
30
31
32
AND
AND
AND
NWA-008847-001 Rev.3.0
33
a6ch1001.fm
JULY/01/2006