Adjust the microphone sensitivity for acoustic room surveillance

If it was detected that the limit level was exceeded when the room surveillance is activat-
ed, the programmed internal call to the required indoor station is triggered. The function
indication for button RED is blinking shortly then is switched on again.
 can be adjusted continuously at the control for motion sensor sensitivity (below the la-
belling of the function keys)
 Set the control of the motion sensor sensitivity with a suitable screwdriver to the maxi-
mum sensitivity (clockwise until the stop). When unintended triggering is caused, reduce
the sensitivity by turning the controller counter-clockwise.
The function can be switched on / off with the button RED. The red LED between the but-
ton is on, if the function is activated.

Ring tone selection

For 4 different incoming calls (door calls from 2 front-door stations, floor call, internal call)
the ring tones can be selected.
1
End voice communication. Press call OFF button for around 8 sec.
Both LEDs are ON and an acknowledgement tone sounds, the ring tone selection
is activated.
By pressing the following buttons, a ring tone can be selected. You can choose be-
tween 13 tones. 7 alpha tones, 6 gong tones.
select door ring tone
2a
of the front-door sta-
tion*
2b
select door ring tone
of the floor door
select internal call to-
2c
ne
select door ring tone
2d
of the second front-
door station
(if available)
3
Press call OFF button shortly.
If no button is pressed for around. 8 sec, the device ends the ring tone selection
automatically. With the output of a signal tone, the ring tone selection is deactivat-
ed.
* The first selection of this door ring tone is adopted for the second front-door station.
Only after selecting the ring tone for second front-door station separately (2b) once, it always has to be selected inde-
pendently.
TCS TürControlSysteme AG, TCS Hotline Germany: +49 41 94/ 9 88 11 88
FAX: +49 41 94/ 9 88 129  Mail: hotline@tcsag.de
14
Press the door release button until the required ring tone
sounds. The ring tone selected last, will be stored.
Press the light switch button until the required ring tone
sounds. The ring tone selected last, will be stored.
Press the control key until the required ring tone sounds.
The ring tone selected last, will be stored.
Press the function key for around 8 seconds until the sig-
nal tone sounds again.
Then, press the door release button until the required ring
tone sounds. The ring tone selected last, will be stored.
Subject to technical changes.