TCS IVW3012-0110 Product Information

TCS IVW3012-0110 Product Information

Video indoor stations color skyline surface/flush-mount
Table of Contents

Advertisement

Quick Links

Video indoor stations color skyline
TCS TürControlSysteme AG
E-Mail: hotline@tcsag.de • www.tcsag.de
Product information
IVW3012-0110 surface-mount
IVW3012-0210 flush-mount
Subject to technical changes.
PI_IVW3012_0x10_uk.doc
IVW3012-0x10
TM

Advertisement

Table of Contents
loading

Summary of Contents for TCS IVW3012-0110

  • Page 1 Product information Video indoor stations color skyline IVW3012-0x10 IVW3012-0110 surface-mount IVW3012-0210 flush-mount TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 2: Table Of Contents

    Select the camera by topstitching with the image button ..........22 Activating / deactivating zoom mode ................23 Navigating in the image with the four navigation keys ............ 23 External image buffer ..................... 23 TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 3: Scope Of Delivery

    Sending and displaying control functions ..............26 Short messages ......................27 Reading short messages .................... 27 Deleting short messages .................... 27 General information on the conduit in TCS video systems ......... 27 6-wire operation ......................27 Loop resistance principle .................... 28 Loop resistance measurement ................... 28 Max.
  • Page 4: Safety Instructions

    When working on systems with a main connection of 230 V alternating voltage, the safety requirements according to DIN VDE 0100 have to be observed. During the installation of TCS:BUS systems the general safety regulation for telecommuni- cation systems according to VDE 0800 have to be observed. Inter alia:...
  • Page 5: Device Overview

    / image reproduction (if mode to store imag- es is activated) call image buffer menu and time setting TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 6 LED is ON: record video / image manually (only if a live image is displayed) if LED blinks: call up image buffer menu press and hold (longer than 4 sec) activate / deactivate automatic image recording TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 7: Intended Use

    / video systems. The operation is realised through buttons and the On-Screen-Display (OSD). The video indoor station IVW3012-0110 is suitable for surface-mount and the video in- door station IVW3012-0210 for flush-mount and cavity wall mounting.
  • Page 8: Short Description

    / stored images available optical operation and error indication, blue (can be switched off) connections connection for floor push button within the device external floor camera (C-terminal) TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 9: Mounting And Installation

    (height ca. 10 mm) connector socket support plate (4 x) connection cable of the front panel unit TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 10: Fixing The Flush-Mount Box

    Use a suitable small screwdriver to connect the lines and to avoid damaging the de- vice. Strip insulation of the line ends. Connect the lines according to the connecting diagram (see also labeling at the type label). TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 11: Connect The Components

    – Loosen the butterfly nuts a little bit. – Change the position of the support plate. – Then tighten the butterfly nuts again. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 12: Disassembly

    Hold the front panel unit with both hands. Press the screwdriver handle slightly to the wall (2). The front panel unit can be removed now (3). Make sure that the ribbon cable is not damaged. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 13: Wiring Example

    Note for LSA terminal points Any forms of LSA terminal points cannot be used to install a TCS:BUS system. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 14: Commissioning

    Open the device. See Disassembling the device, page 12. Put on the terminating resistor horizontally onto both contacts. Delivery state: terminating resistor not plugged *(diagonal, plugged to one contact. Close the device). TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 15: Configuration

    *) The video AS border can be changed with the configuration software configo Note: The AS addresses of the front-door stations have to be allocated with Service Device or configuration software configo TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de...
  • Page 16: Preset Times

    – – coming floor call define internal call destinations (by sending the sender serial number) – – (source display at IMM1100, IMM2100 or IVW3011 / IVW3012 possible) TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 17: Programming The Function Key With The Service Device

    The symbols indicate the buttons that are available in the corresponding screen (e.g. menu control functions). The fade-in automatically ends after 5 seconds or after the first keystroke. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 18: Setting The Menus Internal Calls And Control Functions

    As shown under b), this is displayed by symbols in front of the list entry. Thereby, the control function numbers 01 and 03 generate the state OFF and the numbers 02 and 04 the state ON. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de...
  • Page 19: Receiving Short Messages

    A short message can be distributed to the indoor stations with the help of the SMS proto- col, when sent to a FBI4410. The video indoor station IVW3012 is able to receive short messages via the TCS:BUS. Further it can store and display short messages, if required.
  • Page 20: Adjust Ring Tone Parameter

    Press the navigation button RIGHT (or LEFT) and  go to the symbol ring tone parameter Press the menu button again to call up the menu ring tone parameter. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 21: Adjust Image Parameter

    3 sec after pressing the speech button. Press the image button or the speech button to switch on the live image. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 22: Reset To Factory Setting

    When receiving a door call, the live image from the calling video front-door station (camera) is activated. Press the image button again to switch over to the next video front-door station or cam- era. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 23: Activating / Deactivating Zoom Mode

    (longer than 4 sec) and the image buffer indication lights yellow. The symbol image buffer is displayed in the live image. When receiving a door call, an image is stored auto- matically. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 24: Store An Image Manually

    FVM1000 are deleted or if no images are available when calling up the menu, the illustrated screen (see picture to the right) is displayed for 4 sec. Then the main menu appears again. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 25: Delete All Stored Images

    UP or DOWN. Switch over to the next position by pressing the menu button. By pressing the menu button again the menu- display is switched off. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 26: Internal Calls

    UP or DOWN. Triggering by pressing the menu button. An acknowledgement tone sounds. The OSD is swit- ched off after 5 sec (or switches to the live image). TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 27: Short Messages

    General information on the conduit in TCS video systems 6-wire operation The 6-wire operation is the standard operation mode. Two separated ground lines (b and M) are used in video operation.
  • Page 28: Loop Resistance Principle

    Note: The number of the front-door stations that can be VS power supply and control unit connected is limited and is described in their product infor- IS indoor station mation! TÖ door opener TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 29: Technical Data

    (e.g. FVY) is set correctly. The terminating resistor at the Please plug the terminating resis- end of the strand is not plugged. tor. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 30 The image rolls. The video signal cannot be syn- Please check if all wires of the video chronised. BUS are connected. If ne-cessary please adjust the video level. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_IVW3012_0x10_uk.doc...
  • Page 31: Cleaning

    If necessary, connect this second video source via a video switch to the existing TCS:BUS. No image. Image switch button No signal present. Connect the monitor in front of the does not respond when press- video switch and check whether a ing.
  • Page 32: Conformity

    Please contact us: hotline@tcsag.de. Service Please send your questions and inquiries to hotline@tcsag.de headquarter TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin Telephone.: +49 (0) 3933/879910, FAX: +49 (0) 3933/879911 Mail: info@ tcs-germany.de, www.tcsag.de TCS TürControlSysteme AG Subject to technical changes.

This manual is also suitable for:

Ivw3012-0210