Summary of Contents for TCS ISH3230

  • Page 1 Product information Door telephone with announcement function ISH3230 TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de  www.tcsag.de PI_ISH3230-uk...
  • Page 2: Table Of Contents

    Connect the lines ....................... 9 Connection lines ....................... 9 Wiring example......................... 9 Connection diagram 3-wire technique ................10 Replace an ISH1030 or TTS1 with an ISH3230 ............. 10 Commissioning ........................ 10 Settings ..........................10 Preset times ........................10 Ring tone selection ......................11 Adjust volumes .......................
  • Page 3: Scope Of Delivery

    ZIT3030-0010.  3-wire technique necessary!  The indoor station ISH3230 must not be used in call systems according to DIN VDE 0834 and EN50134.  According to DIN 77800, a separate safeguard for emergency call has to be in- stalled.
  • Page 4: Max. Number Of Ish3230 In 3-Wire Operation

    08/2012 Max. number of ISH3230 in 3-wire operation when using power supply max. number and control unit ISH3230 NBV3210, 3 lines VBVS05 (PSG02), 1 line AS front-door station VS power suply and control unit IS indoor station Note: The number of front-door stations which can be connected is limited. Details are described in respective product...
  • Page 5: Device Overview

    -5 ...+ 40 °C degree of protection: IP30 input current in stand-by I(a) = 0.2 mA, I(P) = 1 mA max. input current: I(Pmax) = 70 mA 3-wire technique necessary! TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_ISH3230-uk...
  • Page 6: Short Description

     Install the lower cover with three screws. TIPP: Avoid tearing of the straps: For fixing at the straps do not use counter-head screws rather use flat washers! TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_ISH3230-uk...
  • Page 7  Snap-on the upper cover below with slight pressure (2) Connect the handset Plug the western connector of the handset cord into the socket at the underside of the telephone. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_ISH3230-uk...
  • Page 8: Open The Device

     The extended functions (and the antenna) have to be fixed in the indoor station with adhesive pads (see also product information of each extended function). * Connecting the lines is realised in analog to the ISH3030 (see product information TRE1-EB/1). TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de...
  • Page 9: Connect The Lines

    Further wires have to be connected with auxiliar terminals! Use only connecting lines with identical diameter in one terminal contact. Wiring example floor push button floor push button TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_ISH3230-uk...
  • Page 10: Connection Diagram 3-Wire Technique

    Replace an ISH1030 or TTS1 with an ISH3230  The floor push-button always has to be connected to the a-wire.  In case of a parallel connection, both telephones must be replaced by an ISH3230. Commissioning  Install the devices of the system voltage-free and completely.
  • Page 11: Ring Tone Selection

    (preset ex works: volume level 6 out of 8) ring tone volume Turn the ring tone volume control when the handset is cradled, no voice communication (preset ex works: volume level 7 out of 8) TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_ISH3230-uk...
  • Page 12: Configuration Options

    0, can be changed in the range from 1 … 63. During an announcement or during a loud tone output the device is blocked for the user, this concerns also door calls, internal calls and floor calls. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de...
  • Page 13: General Information To The Conduit In Tcs Audio Systems

    08/2012 General information on the conduit in TCS audio systems The conduit is determined by structural conditions and is only limited by its length.  Observe when selecting the cables: the loop resistance can amount max. 20 Ω (see table) ...
  • Page 14: Repair

    EEPROM of the front-door station.  Ensure that the new indoor station is connected to the TCS:BUS and the mains voltage is switched on (the operation LED at the power supply and control unit is ON) and fur- ther, that the access to the flat is granted during the programming.
  • Page 15: Cleaning

    Avoid water from entering the device! Do not use any abrasive detergents! Clean the device with a dry or slightly moist cloth. Remove stronger stains with a mild plastic cleaner. TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de PI_ISH3230-uk...
  • Page 16: Conformity

    10 pieces cover panel white 120 x 250 x 2 mm Service Please send your questions and inquiries to hotline@tcsag.de headquarters TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin, Germany E-Mail: hotline@tcsag.de, www.tcsag.de TCS TürControlSysteme AG Subject to technical changes. E-Mail: hotline@tcsag.de • www.tcsag.de...