TCS ISH3022 Product Information

TCS ISH3022 Product Information

Door telephone

Advertisement

TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de
FAX: +49 (0) 41 94/ 9 88 129
Product information
Door telephone
Subject to technical changes.
PI_ISH3022-uk
ISH3022

Advertisement

Table of Contents
loading

Summary of Contents for TCS ISH3022

  • Page 1 Product information Door telephone ISH3022 TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49 (0) 41 94/ 9 88 129 PI_ISH3022-uk...
  • Page 2: Table Of Contents

    Connection lines ....................... 8 Wiring example......................... 8 Connection diagram 2-wire technique ................9 Connection diagram 3-wire technique ................9 Note: Replace an ISH1030 or TTS1 with an ISH3022............9 Commissioning ........................9 Settings ..........................9 2-wire/3-wire operation ..................... 9 Adjust the ring tone volume .................... 10 Configuration ........................
  • Page 3: Scope Of Delivery

    With suitable measures to protect against lightning, it has to be ensured that a voltage of 32 V DC is not to be exceeded at the TCS:BUS wires a and b. TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
  • Page 4: Device Overview

    Intended use  The ISH3022 is an indoor station for duplex communication.  As door telephone it is suitable for the operation within TCS audio systems and com- bined audio/video systems. The signal transmission and power supply is realised with a polarity-free and short-circuit protected 2-wire TCS:BUS.
  • Page 5: Max. Number Of Ish3022 In 2-Wire Operation

    11/2012 Max. number of ISH3022 in 2-wire operation when using power supply max. number and control unit ISH3022 BVS20 or NBV1000, 1 strand BVS100, distributed on 3 strands PSG02, 1 strand Max. number ISH3022 in 3-wire operation when using power supply max.
  • Page 6: Installation

    Connect the handset  Plug in the Western connector of the handset cord into the socket at the underside of the telephone. TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49(0) 41 94/ 9 88 129 PI_ISH3022-uk...
  • Page 7: Open The Device

     The extended functions (and ev. the antenna) have to be fixed in the indoor station with adhesive pads (see also product information of each extended function). TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49 (0) 41 94/ 9 88 129...
  • Page 8: Connect The Lines

    Further wires have to be connected with auxiliar terminals! Use only connecting lines with identical diameter within one terminal contact. Wiring example floor push button floor push button TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49(0) 41 94/ 9 88 129 PI_ISH3022-uk...
  • Page 9: Connection Diagram 2-Wire Technique

    Note: Replace an ISH1030 or TTS1 with an ISH3022  The floor push button always has to be connected to the a-wire.  In case of a parallel connection, both telephones must be replaced with an ISH3022. Commissioning  Install the devices of the system voltage-free and completely.
  • Page 10: Adjust The Ring Tone Volume

    Note: block ring tone output The ring tone output can be blocked with the switch “call OFF” at the Service Device TCSK-01 for 4 min. TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49(0) 41 94/ 9 88 129...
  • Page 11: General Information On The Conduit In Tcs Audio Systems

    11/2012 General information on the conduit in TCS audio systems The conduit is determined by structural conditions and is limited only by its length.  Observe when selecting the cable length: the loop resistance must not exceed 20 Ω (table) ...
  • Page 12: Technical Data

    The number is stored in the EEPROM of the front- door station.  Ensure that the new indoor station is connected to the TCS:BUS and that the mains voltage is switched on (the operation LED at the power supply and control unit is on).
  • Page 13 (see product information of the front-door station). *) for device specific indication modes of the front-door station see product information of the front-door station TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
  • Page 14: Cleaning

    Short text Article number E32431 10 x lower cover ISx3xxx-x140 E24340 10 pieces cover plate white120 x 250 x 2 mm TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49(0) 41 94/ 9 88 129 PI_ISH3022-uk...
  • Page 15 11/2012 TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49 (0) 41 94/ 9 88 129 PI_ISH3022-uk...
  • Page 16: Service

    Service Please send your questions and inquiries to hotline@tcsag.de Headquarters TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin Tel.: +49 (0) 3933/879910, FAX: +49 (0) 3933/879911, www.tcsag.de TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49(0) 41 94/ 9 88 129...

Table of Contents