With suitable measures to protect against lightning, it has to be ensured that a voltage of 32 V DC is not to be exceeded at the TCS:BUS wires a and b. TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Intended use The ISH3022 is an indoor station for duplex communication. As door telephone it is suitable for the operation within TCS audio systems and com- bined audio/video systems. The signal transmission and power supply is realised with a polarity-free and short-circuit protected 2-wire TCS:BUS.
11/2012 Max. number of ISH3022 in 2-wire operation when using power supply max. number and control unit ISH3022 BVS20 or NBV1000, 1 strand BVS100, distributed on 3 strands PSG02, 1 strand Max. number ISH3022 in 3-wire operation when using power supply max.
Connect the handset Plug in the Western connector of the handset cord into the socket at the underside of the telephone. TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49(0) 41 94/ 9 88 129 PI_ISH3022-uk...
The extended functions (and ev. the antenna) have to be fixed in the indoor station with adhesive pads (see also product information of each extended function). TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49 (0) 41 94/ 9 88 129...
Further wires have to be connected with auxiliar terminals! Use only connecting lines with identical diameter within one terminal contact. Wiring example floor push button floor push button TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49(0) 41 94/ 9 88 129 PI_ISH3022-uk...
Note: Replace an ISH1030 or TTS1 with an ISH3022 The floor push button always has to be connected to the a-wire. In case of a parallel connection, both telephones must be replaced with an ISH3022. Commissioning Install the devices of the system voltage-free and completely.
Note: block ring tone output The ring tone output can be blocked with the switch “call OFF” at the Service Device TCSK-01 for 4 min. TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49(0) 41 94/ 9 88 129...
11/2012 General information on the conduit in TCS audio systems The conduit is determined by structural conditions and is limited only by its length. Observe when selecting the cable length: the loop resistance must not exceed 20 Ω (table) ...
The number is stored in the EEPROM of the front- door station. Ensure that the new indoor station is connected to the TCS:BUS and that the mains voltage is switched on (the operation LED at the power supply and control unit is on).
Page 13
(see product information of the front-door station). *) for device specific indication modes of the front-door station see product information of the front-door station TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Short text Article number E32431 10 x lower cover ISx3xxx-x140 E24340 10 pieces cover plate white120 x 250 x 2 mm TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes. FAX: +49(0) 41 94/ 9 88 129 PI_ISH3022-uk...