Safety Instructions - TCS IMM2500 Product Information

Indoor station with special functions for hands-free talking
Table of Contents

Advertisement

Mounting, installation, commissioning and repair of electronic devices have to be car-
!
ried out only by qualified electricians!
For working on systems with a main connection of 230 V alternating voltage, the safety
regulations according to DIN VDE 0100 must be observed.
When installing TCS:BUS systems the general safety regulations for telecommunication
systems according to VDE 0800 must be observed.
 separated guidance of heavy and low current lines,
 minimum distance of 10 cm in case of a common conduit,
 use of separators between heavy and low current lines within shared cable ducts,
 use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
 already existing lines (modernisation) with deviating cross-sections can be used in
compliance with the loop resistance.
With suitable measures to protect against lightning, it has to be ensured that a voltage
!
of each 32 V DC is not exceeded at the TCS:BUS wires a and b.
 The indoor station IMM2500 must not be used in call systems according to DIN
VDE 0834 and EN50134.
 According to DIN 77800, a separate safeguard for emergency calls has to be in-
stalled.
 A system equipped with an indoor station IMM2500 is not an emergency call sys-
tem according to the above mentioned standards.
 The system equipped with an indoor station IMM2500 must not be used in life-
saving or life-sustaining systems.
 Further, the combination of system parts which fulfill the above mentioned
standards is not permitted.
TCS TürControlSysteme AG, TCS Hotline Germany: +49 41 94/ 9 88 11 88