1.2

Assembly

Assemble a new machine harness in the reverse order of removal.
Step1
Reconnect the connector, round terminal, and air tubes.
NOTE
Refer to the separate document "XE Series Installation Manual" for wiring diagrams.
Step 1 Assembly
Tighten the nut so that the machine harness is
not pulled out when stretching it and it does not
slip when twisting it 90°.
Be careful not to break the air tube
when reattaching the cover.
Step2
Clamp the machine harness on the
Y-axis side.
For the machine harness clamp position on
the Y-axis side, clamp the machine harness
at a specified position while referring to the
Fig.
L (mm)
508
Tighten the nut so that the machine harness is not pulled out
when stretching it and it does not slip when twisting it 90°.
Be careful not to break the air tube
when reattaching the cover.
Tighten the lock nut firmly so
that it does not become loose.
Step 2
Clamping
53609-FV-00
6
53608-FV-00
6-5