Opc Ua Error Messages - Siemens SIMATIC RF600 Series Configuration Manual

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

"ER"
XML/
PLC block
LED
LED
(hex)
(hex)
--
0x97
0xE7FE09
--
0x7A
0xE7FE0A
"--" means that the error is not displayed by the LEDs.
13.2.3

OPC UA error messages

The following table lists the OPC UA-specific error codes.
Table 13- 3
OPC UA error messages of the RF600 readers
AutoId
XML/
OPC UA
status
LED
status
(hex)
1
0xCA
good
1
0xCD
good
1
0xE6
good
1
0xEA
good
1
0xEB
good
3
0x1A
good
4
0x92
good
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
Error description
Command repetition is not supported.
Error during the transfer of the PDU (Protocol Data Unit).
AutoId
text
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
PERMISSON_
ERROR
PASSWORD_
ERROR
Error description
General error
Firmware error
Possible cause: The firmware update was not run
completely.
Internal communications error of the communications
module/reader
Connector contact problem on the communica-
tions module/reader
Hardware of the communications module / reader
has a defect; → Send in communications module /
reader for repair
Start "INIT" after correcting the error
Internal monitoring error of the communications mod-
ule/reader
Program execution error on the communications
module / reader
Turn the power supply of the communications
module/reader off and on again
Start "INIT" after correcting the error
The inventory command failed.
Enabling write protection on the transponder failed.
The "Kill" command failed.
The transponder is read/write-protected.
The transponder password is incorrect. Access is denied.