9.5.1.5

Reader_Status

The "Reader_Status" block reads status information from the reader. For the RF68xR
reader, there is only the status mode "0x89" that is selected using the "ATTRIBUTE"
parameter. The status data is returned as "Array of Byte".
Figure 9-6
Table 9- 5
Parameter
ATTRIBUTE
IDENT_DATA
Results
Table 9- 6
ATTRIBUTE "0x89" ("IID_READER_STATUS_89_RF68xR" data type)
Name
status_info
hardware_version
firmware_version
config ID
inventory_status
sum of filtered tags
filtered_smoothing
filtered_blacklist
filtered data-filter
filtered RSSI thresold
filtered RSSI delta
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
"Reader_Status" block
Explanation of the "Reader_Status" block
Data type
SINT
SINT[10]
Type
Comment
BYTE
SLG-Status mode(Subcommand)
BYTE
Version of hardware
ARRAY[1..4] of
Version of firmware
CHAR
DWORD
Unix timestamp
WORD
0=inventory not active;1=inventory active;2=presence
mode active
WORD
All filtered Tags
Filtered Tags trough Smoothing
WORD
Filtered Tags trough Blacklist
WORD
WORD
Filtered Tags trough Data-Filter
WORD
Filtered Tags trough RSSI Threshold
WORD
Filtered Tags trough RSSI Delta
Programming via Rockwell controller
9.5 Programming add-on instructions
Default values
Description
B#16#81
Identifier of the status mode "0x89"
Note: The default value is not valid for
RF680R/RF685R and needs to be
adapted.
0
Event values depending on attributes
Note.
When necessary a byte/array of any
size can be transferred to this parame-
ter. Note that the array must be ≥ 10
bytes long (e.g. "SINT[12400]").
117