Parameter
Parameter
value_id
value_tagID
value_tagPC
value_utcTime
value_
antennaName
value_rSSI
value_channel
value_power
value_polarization
10.4.1.3

ioEventReport

An I/O event report signals changes at an input or output.
In the WBM, the sending of I/O events can be configured. You will find more information on
events in the section "The "Settings - Communication" menu item (Page 71)".
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
Type
Values
Decimal value
0...4294967295
0...9
Hexadecimal
--
value
0...9, A...F
Hexadecimal
--
value
0...9, A...F
Time
--
Fixed values
Antenna01
Antenna02
Antenna03
Antenna04
Decimal value
0...255
0...9
Decimal value
1...50
0...9
Decimal value
0, 5.00...33.00
0...9
Fixed values
Circular
Vertical
Horizontal
Unknown
Programming via XML interface
10.4 XML EventReports
Description
Unique command identifier
EPC-ID in "RAW Hex Data Format".
Example of a 96-bit EPC-ID:
3005FB63AC1F3681EC880468
For additional information, refer to the
"EPC Global Specification".
Optional
Tag PC (Protocol Control)
16-bit value represented by four hexa-
decimal characters.
Example:
The value "1234" corresponds to the
binary value "0001.0010.0011.0100".
UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.
Name of the antenna
RSSI value
This is a value without a unit and with-
out direct reference to the power
strength.
Optional
Channel number on which the tran-
sponder was detected.
Optional
Used radiated power of the antenna in
[dB]
Increment: 0.25 dB
Polarization of the antenna.
With external antennas always un-
known.