Getblacklist - Siemens SIMATIC RF600 Series Configuration Manual

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

Programming via XML interface
10.3 XML commands
10.3.3.2

getBlackList

With this command, all EPC-IDs currently stored in the black list are queried.
The black list is a filter mechanism with which transponders can be filtered out.
Transponders whose IDs are stored in the black list are ignored and not processed.
Command
<frame>
<cmd>
</cmd>
</frame>
Reply
<frame>
<reply>
</reply>
</frame>
// opt → Optional: Line can be omitted.
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".
174
<id> value_id </id>
<getBlacklist>
<sourceName> value_sourceName </sourceName>
</getBlacklist>
<id> value_id </id>
<resultCode> 0 </resultCode>
<getBlacklist>
<returnValue>
<tagID> value_tagID </tagID>
...
<tagID> value_tagID </tagID>
</returnValue>
</getBlacklist>
// opt
// opt
Configuration Manual, 11/2018, C79000-G8976-C386-07
SIMATIC RF600

Hide quick links:

Advertisement

Table of Contents
loading