Parameter
value_
subNetMask
value_gateway
value_
dHCPEnable
10.3.1.5

getIPConfig

This command is available as of API V2.2.
The current IP address of the reader is read out with this command.
Command
<frame>
<cmd>
</cmd>
</frame>
Reply
<frame>
<reply>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
Type
IP address
IP address
Fixed values
<id> value_id </id>
<getIPConfig/>
<id> value_id </id>
<resultCode> 0 </resultCode>
<getIPConfig>
<iPAddress> value_iPAddress </iPAddress>
<subNetMask> value_subNetMask </subNetMask>
<gateway> value_gateway </gateway>
<dHCPEnable> value_dHCPEnable </dHCPEnable>
<getIPConfig/>
Values
Description
1.0.0.1...
Subnet mask of the reader
255.255.255.254
Parameter is ignored, if DHCP is acti-
vated:
value_dHCPEnable = True
1.0.0.1...
Gateway of the reader
255.255.255.254
Parameter is ignored, if DHCP is acti-
vated:
value_dHCPEnable = True
True
Use of DHCP to assign the IP address.
False
Programming via XML interface