9.2.4
OPC UA error messages
The following table lists the OPC UA-specific error codes.
Table 9- 6
OPC UA error messages of the communication module
AutoId
OPC UA
status
status
1
good
1
good
1
good
1
good
1
good
3
good
4
good
5
Bad
Invalid
Argument /
good
7
good
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 03/2022, C79000-G8976-C512-04
AutoId
text
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
PERMISSON_
ERROR
PASSWORD_
ERROR
REGION_NOT_
FOUND_ERROR
OUT_OF_RANGE_
ERROR
Error description
General error
•
Firmware error
Possible cause: The firmware update was not run
completely.
•
Internal communication error of the communication
module/reader
Connector contact problem on the communication
–
module / reader
Hardware of the communication module/reader has a
–
defect; → Send in communication module/reader for
repair
Start "INIT" after correcting the error
–
•
Internal monitoring error of the communication
module/reader
Program execution error on the communication module /
–
reader
Turn the power supply of the communication
–
module/reader off and on again
Start "INIT" after correcting the error
–
The inventory command failed.
Enabling write protection on the transponder has failed.
The "Kill" command failed.
The transponder is read/write-protected.
The transponder password is incorrect. Access is denied.
All commands:
A parameter of an OPC UA command has an invalid value.
"ReadTag"/"WriteTag" command:
The addressed memory area is not available in the current
transponder.
Address error
The address range of the transponder has been exceeded.
Possible causes:
•
Start address of the command start has been incorrectly set.
•
Wrong transponder type
•
The area to be written to is write-protected.
Service and maintenance
9.2 Error messages