Assigning The Ip Address / Device Name With The Pst - Siemens SIMATIC RF600 Series Configuration Manual

Hide thumbs Also See for SIMATIC RF600 Series:
Table of Contents

Advertisement

● Operating RF615R/RF680R/RF685R readers as S7 users in an automation environment
The unique assignment for PROFINET operation is based on the device name using the
TIA Portal (as of STEP 7 Basic / Professional V13).
In PROFIBUS operation via a communications module an IP address needs to be
assigned only for configuration and diagnostics purposes.
● Operating RF680R/RF685R readers as a Rockwell user in an automation environment
The unique assignment is made using the IP address.
The RF650R reader ships with the IP address "192.168.0.254" set in the factory. In the
factory settings, the RF615R, RF680R and RF685R readers are set to DHCP. With the aid of
the tools listed and the WBM (as of firmware V3.0) you can change IP addresses.
These alternative methods are described below.
4.4.1

Assigning the IP address / device name with the PST

Requirement
The Primary Setup Tool (V4.2 or higher) is installed and the RF600 reader is connected and
has started up. You can find the Primary Setup Tool on the DVD supplied with the reader or
on the pages of "Siemens Industry Online Support
(https://support.industry.siemens.com/cs/ww/de/view/19440762)".
Procedure
Follow the steps below to assign a new, unique IP address and a unique device name to the
reader:
1. Call up the Primary Setup Tool with "Start > All Programs > Siemens Automation >
SIMATIC > Primary Setup Tool".
2. In the menu bar under "Settings > Set PG/PC interface..." select the network adapter via
which the reader is connected to the PC and confirm with "OK".
3. Click on the "Search"
A dialog box opens with the information that a device was found in the network.
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
icon in the toolbar.
4.4 Assign the IP address / device name
Commissioning
27