writeTagID

This command writes a new EPC-ID to the transponder. To ensure clear identification when
writing the ID, there must be only one transponder in the antenna field. If there is more than
one transponder in the antenna field, a negative reply is returned.
Command
<frame>
<cmd>
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
Type
Decimal value
0...9
Decimal value
0...9
Decimal value
0...9
Fixed values
Decimal value
0...9
Fixed values
<id> value_id </id>
<writeTagID>
<sourceName> value_sourceName </sourceName>
<tagID> value_tagID </tagID>
<newID> value_newID </newID>
<idLength> value_idLength </idLength>
<password> value_password </password>
Values
Description
0...255
Optional
Largest measured RSSI value
1...50
Optional
Channel number on which the tran-
sponder was detected.
0, 5.00...33.00
Optional
Used radiated power of the antenna in
[dB]
Increment: 0.25 dB
Default
Optional
Circular
Polarization of the antenna
Linear_vertical
Currently, this parameter can only be
Linear_horizontal
set for the internal antenna of the
All
RF685R.
0...65535
Optional
Indicates how often the transponder
was identified via the air interface be-
fore it changed to the "Observed" sta-
tus.
True
Optional
False
Indicates whether or not a filter criteri-
on was received.
True:
All the data was read or there was
no filter set.
False:
Data could not be read.
// opt
// opt
// opt
Programming via XML interface
10.3 XML commands
183