Supply Setup

Fig. 14
Key
Description
Cycles/min
Cycles/min of supply air motor
High limit
High limit Input Field
High Limit
When the high limit value is reached the machine
will fault. To recover the Supply pump must be
placed in the Manual mode before returning to Auto
mode. See Supply Pumps section in this manual.
Low Level Shutdown time
Amount of time machine will be able to run before
the system shuts down. To recover Supply pump
must be placed in the Manual Mode before returning
to Auto mode. See Supply Pumps section in this
manual.