Mixer Flush
Machines equipped with Solvent
Flush Hardware Refer to Fig. 2
Use fluids and solvents that are compatible with the
equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent
manufacturer's warnings. For complete information
about your material, request MSDS forms from your
distributor or retailer.
Fig. 36
Key
Description
1
Solvent Inlet port
2
System Air
3
Check Valve
4
A side hose
5
B Side hose
6
Fittings to Upper Dispense Block
CAUTION
Ball valves must remain closed as shown in Fig. 36
during normal operation. Opening valves during
dispense operation could cause the machine to
malfunction or become damaged.
58
For information on solvent pump option see
manual 308116.
CAUTION
Solvent Flush will help prevent the static mixer from
curing material during machine down time. It is
recommended to remove the Lower Dispense Block
and Mixer daily for cleaning.