Technical Data - Graco DC12 Operation & Setup

High-volume metering system
Table of Contents

Advertisement

Technical Data

Standard Volume Ratios
Maximum Flow Rate (1)
Maximum Fluid Pressure
Material Supply System
Power Requirements (2)
Maximum Air Consumption (3)
Sound Power Level (6)
Sound Pressure Level (6)
Maximum Inlet air pressure
Optional Tandem Pump(s)
68
Category
Motionless Mixer
Wetted Components
Platen Wipers
Air Inlet size
Weight (4)
Dimensions (5)
Optional Boom
(1)
(2)
(3)
(4)
(5)
(6)
120-240V/1PH/50-60 HZ, 6 Amp
86 in (2.18m) L x 48 in (1.22m) W x 80 in (2.0m) H
86 in (2.18m) W x 110 in (2.8m) H
36 in (.9m) L x 48 in (1.22m) W
Low Density Tooling Paste Up to 6 Kg/Min
Base unit is pneumatic. Power is required for optional
Performance Monitor Plus control
Required compressed air volume for 10 L/min flow
112 in (2.84m) H with Supply Ram in the up position
Sound level at 100 psi (6.9 bar) at 20 cycles/min
Sound pressure level 1 meter from equipment
Data
Other ratios, consult factory
10 L/min
24 elements X 1 in Dia
2,500 psi (172 bar)
Carbon Steel
Dual NXT 55 gal (200 L)
EPDM
60 SCFM
90 dB(A)
79 dB(A)
100 psi (6.9 bar)
3/4 NPT
2,550 lbs (1,156 Kg)
At 1:1 volume ratio
Material weight not included
312767B
2:1
1:1

Advertisement

Table of Contents
loading

Table of Contents