Interfaces; Overview - Siemens SINUMERIK 828D Manual

Ppu
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Spare parts/accessories
11.2 MCP 310C PN
LEDs
Table 11- 17 LEDs: Status display
Name
Designation
H1
PowerOK
H2
PNSync
H3
PNFault
Note
When the system is booting, all three LEDs are lit.
Equipotential bonding
The equipotential bonding conductor is attached by means of an M5 screw.
11.2.3

Interfaces

11.2.3.1

Overview

Overview
X10
X20
X21
X30
X31
X51 / X52 / X55
X53 / X54
X60 / X61
S1
S2
100
Color
Description
Green
Lit: Power supply ok
Green
Lit: System software running, STOP state
Flashes 0.5 Hz: System software running, RUN state
Red
Not lit: Module is operating without errors; data exchange with all configured IO Devices
is running.
Lit: Serious bus fault; only output when one of the following errors is detected for the
ports:
No physical connection to a subnet/switch
Incorrect transmission rate
Full duplex transmission is not activated.
Power supply interface
PLC I/O Interface port 1
PLC I/O Interface port 2
Interface for rotary switch feed override
Interface for rotary switch spindle override / EMERGENCY STOP
(optional)
Interfaces for customer-specific inputs
Interfaces for customer-specific outputs
Reserved
Reserved
Switch for setting the MCP address
Manual, 06/2009, 6FC5397-2DP10-0BA0