Advertisement

Do not connect any relays, valves or other inductive loads.
Connector designation:
Connector type:
Table 11- 8
Pin
1
2
3
4
Table 11- 9
Pin
1
2
3
4
Switch S2
Switch position: "ON" is at the top.
Table 11- 10 Switch S2 is set as delivered
1
OFF
The two switches S2-9 and S2-10 must remain set to "ON".
The switches S2-1 to S2-8 define the MCP address. In SINUMERIK 828D, the address "64"
must always be assigned to the MCP.
PPU
Manual, 06/2009, 6FC5397-2DP10-0BA0
CAUTION
Assignment of connector X53
Signal name
KT-OUT1
KT- OUT2
KT- OUT3
M
Assignment of connector X54
Signal name
KT-OUT4
KT- OUT5
KT- OUT6
M
2
3
4
OFF
OFF
OFF
X53, X54
4-pin plug connector
Signal type
Meaning
Output 1 lamp
O
Output 2 lamp
Output 3 lamp
V
Ground
Signal type
Meaning
Output 4 lamp
O
Output 5 lamp
Output 6 lamp
V
Ground
5
6
7
8
OFF
OFF
OFF
OFF
Spare parts/accessories
11.1 MCP 483C PN
9
10
Meaning
ON
ON
PLC I/O Interface
Address "0"
85