Spare parts/accessories
11.1 MCP 483C PN
Tension jacks
The machine control panel is mounted from the front in a rectangular cutout.
It is secured with nine clamping fixtures (tightening torque 0.5 Nm, see dimension drawing),
which are included in delivery.
Clamping fixtures can also be obtained as spare parts (see section: "Spare parts" →
"Overview").
Figure 11-9
Panel cutout of MCP 483C PN
Mounting position
Max. 60° to the vertical.
For mounting positions greater than 60°, a fan must also be installed to keep the
environmental temperature of the machine control panel constantly below 55 °C.
11.1.5

Connection

Two equivalent connections (Fast Ethernet) are available for establishing the PLC I/O
Interface communication network based on PROFINET (see System overview (Page 11)).
The Ethernet cables are not included in the scope of delivery. When connecting the machine
control panel to the SINUMERIK 828D, please use the preassembled SINAMICS DRIVE-
CLiQ signal cables; from a technical point of view, these are also suitable for use with
PROFINET. They must be ordered separately, see Ordering data (Page 15).
Securing Ethernet cables
Two cable ties are included in the scope of delivery. These are used to secure the Ethernet
cables on the cover plate on the rear of the machine control panel (see figure in section:
"Operator controls and display elements" --> "rear side").