Input / Output Images - Siemens SINUMERIK 828D Manual

Ppu
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Switch S2
Switch position: "ON" is at the top (as with MCP 483C PN).
Table 11- 27 Switch S2 is set as delivered
1
OFF
The two switches S2-9 and S2-10 must remain set to "ON".
The switches S2-1 to S2-8 define the MCP address. In SINUMERIK 828D, the address "64"
must always be assigned to the MCP.
Table 11- 28 Settings of switch S2
1
ON
OFF
11.2.3.3

Input / output images

Input image
The specifications for assigning input and output bytes listed in the tables are set as
standard addresses in the PLC by setting the following machine data:
MD12986 PLC_DEACT_IMAGE_LADDR_IN[6] = -1
Table 11- 29 Input image MCP 310C PN
Byte
Bit7
EB112
* NC
Stop
EB113
NC
Start
EB114
Feed
Start
EB115
RESET
EB116
+
EB117
T16
EB118
T9
PPU
Manual, 06/2009, 6FC5397-2DP10-0BA0
2
3
4
OFF
OFF
OFF
OFF
2
3
4
ON
ON
ON
OFF
OFF
OFF
OFF
Bit6
Bit5
Spindle
Spindle -
100%
Spindle
* Spindle
right
stop
* Feed
INC VAR
Stop
Keyswitch
Keyswitch
position 2
position 1
Direction keys
-
Rapid
traverse
KT6
6
Unassigned customer keys
T10
T11
5
6
7
8
OFF
OFF
OFF
5
6
7
8
ON
ON
ON
ON
OFF
ON
OFF
Bit4
Bit3
Single
Spindle +
block
Spindle
Keyswitch
left
position 3
Keyswitch
position 0
INC 1000
E (2
)
D (2
4
3
KT5
KT4
5
4
T12
WCS
MCS
Spare parts/accessories
11.2 MCP 310C PN
9
10
Meaning
ON
ON
PLC I/O Interface
Address "0"
9
10
Meaning
ON
ON
DCP mode
Address "64"
Bit2
Bit1
JOG
MDA
REF
REP
INC 100
INC 10
Feedrate override
)
C (2
)
B (2
2
KT3
KT2
Z
Y
Unassigned customer keys
T13
T14
Bit0
AUTO
Teach
IN
INC 1
)
A (2
)
1
0
KT1
X
T15
105

Hide quick links:

Advertisement

Table of Contents
loading