Tension jacks
The machine control panel is attached using 6 tension jacks (tightening torque, 0.5 Nm).
Figure 11-19 Panel cut-out for the machine control panel MCP 310C PN
Mounting position
Max. 60° to the vertical.
For mounting positions greater than 60°, a fan must also be installed to keep the ambient
temperature of the machine control panel constantly below 55 °C.
11.2.5

Connection

Two equivalent connections (Fast Ethernet) are available for establishing the PLC I/O
Interface communication network based on PROFINET (see System overview (Page 11)).
The Ethernet cables are not included in the scope of delivery. When connecting the machine
control panel to the SINUMERIK 828D, please use the preassembled SINAMICS DRIVE-
CLiQ signal cables; from a technical point of view, these are also suitable for use with
PROFINET. They must be ordered separately, see Ordering data (Page 15).
Securing the cables
Two cable ties are included in the scope of delivery. These are used to secure the Ethernet
cables on the cover plate on the rear of the machine control panel (see figure in section:
"Operator controls and display elements" --> "rear side").
NOTICE
Make sure that all cables are routed so that they do not come into contact with chafing
edges.