Download Print this page

Avaya S87 0 Series Configuration Note page 8

Emea

Advertisement

Tip:If the numbering format is set to unk-pvt
then the PBX looks to the Private-Numbering
Table to build the number. The Network Level
must not be left blank (in most cases this is set
to 0) or NO number will be sent.
This is where the PBX builds the called party
number for the integration. If it is set to
unknown, the PBX looks at the Public-
Unknown table where an entry is required to
build to the number. If there is no entry in this
table to build the number, NO number is sent.
For Avaya CM 4.0 and later see related
note below
AVAYA E1/QSIG
Create a trunk group, and assign the newly created DS1 channels to it. If the
MAS will be configured to perform outcalls, ensure that the COR (Class of
Restriction) assigned to this trunk group allows for outside trunk access. The trunk
group must be configured as follows:
display trunk-group 1
Group Number: 1
Group Name: QSIG - E1
Direction: two-way
Dial Access? n
Queue Length: 0
Service Type: tie
TestCall BCC: 4
TRUNK PARAMETERS
Codeset to Send Display: 6
Max Message Size to Send: 260
Supplementary Service Protocol: b
Trunk Hunt: cyclical
Calling Number - Delete:
Bit Rate: 1200
Disconnect Supervision - In? y
Answer Supervision Timeout: 0
display trunk-group 1
TRUNK FEATURES
ACA Assignment? n
Used for DCS?
n
Suppress # Outpulsing? n
Outgoing Channel ID Encoding: exclusive
Send UCID? n
Send Codeset 6/7 LAI IE? y
Path Replacement with Retention? n
Path Replacement Method: always
NOTE 1: NCA-TSC Trunk Member should have the highest timeslot from the
upper E1 span in the trunk group. For example, if there is one E1 span in the
MAS then it should be 29, and if there are 2 spans then its should be 59.
NOTE 2: The Numbering Format fields could be set according to the customer's
environment. There are many variations plus other tables associated with these
fields that must be considered also. Consult with a Software Specialists for proper
programming.
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
TRUNK GROUP
Group Type: isdn
COR: 1
Outgoing Display? y
Busy Threshold: 99
Auth Code? n
Far End Test Line No:
Codeset to Send National IEs: 6
Charge Advice: none
Digit Handling (in/out): enbloc/enbloc
Insert:
Synchronization: async
Out? n
Measured: none
Internal Alert? n
Data Restriction? n
Send Name: y
Hop Dgt?
n
Numbering Format: unk-pvt (see Tip & NOTE2 below)
UUI IE Treatment: service-provider
Replace Restricted Numbers? n
Replace Unavailable Numbers? n
Send Called/Busy/Connected Number: y
Network (Japan) Needs Connect Before Disconnect? n
8
Page
1 of
22
CDR Reports: y
TN: 1
TAC: 21
Carrier Medium: PRI/BRI
Night Service:
TestCall ITC: rest
QSIG Value-Added? n
Digital Loss Group: 13
Numbering Format: unk-unk
Duplex: full
Page
2 of
22
Wideband Support? n
Maintenance Tests? y
NCA-TSC Trunk Member: 29 (Note1)
Send Calling Number: y
Ds1 Echo Cancellation? n
Modify Reroute Number? y

Advertisement

loading

This manual is also suitable for:

S8 0 seriesDefinity g3Prologix