AVAYA E1/QSIG
The Remote switch (DCS Node 2) does not require changes on the DCS Trunk
Group incoming to the Hub Node. However the Signaling Group for this Trunk
Group requires changes. The following is an example of the changes highlighted
in boldface:
change signaling-group 7
Group Number: 7
Associated Signaling? y
Primary D-Channel: 01A0824
Trunk Group for Channel Selection: 7
Supplementary Service Protocol: a
display signaling-group 7
Service/Feature:
TSC
Local
Index
Ext.
Enabled Established
1:
2299
y
2:
6451
y
3:
n
4:
n
5:
n
etc..
Create a Hunt Group for messaging from the remote Node.
display hunt-group 2
Group Number: 2
Group Name: S3400 VOICEMAIL REMOTE
Group Extension: 6300
Group Type: ucd-mia
COR: 8
Security Code:
ISDN Caller Display:
display hunt-group 2
Voice Mail Extension: 3000
Send Reroute Request: y
Calling Party Number to INTUITY AUDIX? y
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
SIGNALING GROUP
Group Type: isdn-pri
ADMINISTERED NCA TSC ASSIGNMENT
As-needed Inactivity Time-out (min):
Dest. Digits
permanent
2100
permanent
3081
HUNT GROUP
TN: 1
Night Service Destination:
HUNT GROUP
Message Center: rem-vm
LWC Reception: none
36
Page
1 of
Max number of NCA TSC: 16
Max number of CA TSC: 31
Trunk Group for NCA TSC: 7
Page
2 of
Mach.
Appl.
ID
dcs
1
audix
1
Page
1 of
ACD? n
Queue? n
Vector? n
Coverage Path:
MM Early Answer? n
Page
2 of
5
5
10
10