Configuring the MAS
Special Note: Verify the CRC value in the QTE.PRM is set correctly. If left uncorrected the Dialogic E1 boards
will not initialize properly.
Open the
qte.prm
file. About 23 lines into the file text you will see a setting under the line as show in bold below.
;---
;--- CRC ENABLE SWITCH (Parameter type 0FH - E1 only)
;--- Turns the transmission of the CRC4 pattern on or off and searches
;--- for such a pattern in the received signal.
;--- Possible values for the data are as follows:
;---
;---
;--- The default data value is 00H (Turn CRC off).
000F 01
The example number shown above in
Save then file and then reboot the MAS.
AVAYA E1/QSIG
6.0 CONFIGURING THE MESSAGE APPLICATION SERVER
Configuring the MAS platform for proper PBX integration requires configuring
several menus accessed within the Voice Mail System Configuration application, and
Access the Voice Mail System Configuration application from the
MAS program group.
The file is found in:
C:\Program
Files\Dialogic\data\qte.prm
00H = Turn CRC off.
01H = Turn CRC on.
blue
is incorrect. Change this from
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
a certified MM engineer.
to
000F 01
000F 00.