AVAYA E1/QSIG
Create a Call Coverage Path that will be assigned to the subscribers' stations.
This Call Coverage Path will have the MAS Hunt Group as the Call Coverage Point.
Below is an example of a Call Coverage Path.
display coverage path 10
Coverage Path Number: 1
COVERAGE CRITERIA
Station/Group Status
Active?
Busy?
Don't Answer?
All?
DND/SAC/Goto Cover?
COVERAGE POINTS
Terminate to Coverage Pts. with Bridged Appearances? n
Point1:h1
Point4:
Configure the subscriber stations, assigning the newly created Call Coverage
Path (i.e. 10) to them. Also, ensure the following setting for subscribers:
display station 3002
Extension: 3002
Type: 8410D
Port: 01A0102
Name: Smith John
STATION OPTIONS
Loss Group: 2
Data Module? n
Display Module? y
Speakerphone: 2-way
Display Language: english
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
COVERAGE PATH
Next Path Number:
Inside Call
Outside Call
n
y
y
n
y
Point2:
Point5:
STATION
Lock Messages? n
Security Code:
Coverage Path 1: 10
Coverage Path 2:
Hunt-to Station:
Personalized
Ringing Pattern
Message Lamp Ext: 3002
Mute Button Enable? y
14
Hunt after Coverage? n
Linkage
n
y
y
Number of Rings: 4
n
y
Point3:
Point6:
Page 1 of 4
BCC: 0
TN: 1
COR: 1
COS: 1
:
1