Download Print this page

Avaya S87 0 Series Configuration Note page 31

Emea

Advertisement

AVAYA E1/QSIG
intentionally chosen a particular Trunk Group for the outgoing
call. ANF-PR will not replace the path in this case.
8.9
The Communication Manager does not support call queuing on
QSIG trunks. Hence, calls cannot be queued to MAS ports. The
user audible behavior is that during peak traffic, when all MAS ports
are busy, a caller will hear a fast busy. They should hang up and try at a
later time.
8.10 When configuring an N+1 MM environment the following changes
should be made to the MAS Service in the services applet, all steps
should be completed:
1. Double click the Monitor icon on the desktop.
2. Select Services
3. Locate the Message Application Service
4. Right click the Message Application Service and select properties
from the menu.
5. Select the Recovery tab.
6. For First Failure select Run File.
7. Select the Browse button and locate the QSIGRecover file:
\\Avaya_Support\Tools\QSIGRecover\QSIGRecover.exe
8. Enter the following in the Command Line Parameters box:
If you have one E1 board in your MAS:
/recover /boards 1
If you have two E1 boards in your MAS:
/recover /boards 2
If you have three E1 boards in your MAS:
/recover /boards 3
9. Check the Append fail count to end of command line checkbox.
10. Repeat steps 6 to 8 for Second Failure.
11. For Subsequent Failures select Reboot The Computer.
12. Select OK to save changes.
13. Select Run from the Start Menu
14. Enter cmd and select OK
15. At the command prompt navigate to the
Avaya_Support\Registry_Keys folder.
16. Enter the following: stopdriversonshutdown.reg and press the
return key. Note: This registry file will apply a change to the
registry key to stop the Dialogic drivers when the MAS service is
stopped.
17. Close the command prompt.
8.11 Trunk-to-Trunk is not required to support Find Me if the minimum
releases indicated below are met. Previously, when a public network
call arrived at an Avaya™ Communication Manager system and was
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1