AVAYA E1/QSIG
In the remote Node AAR Analysis table route 4573000 to route pattern 2.
display aar analysis 2
Dialed
String
4573000
In the remote Node Route Pattern 2 insert the MAS AAR Access code of 107.
display route-pattern 2
Grp. FRL NPA Pfx Hop Toll No.
No.
Mrk Lmt List Del
1: 7
0
2:
3:
4:
5:
6:
BCC VALUE
TSC CA-TSC
0 1 2 3 4 W
Request
1: y y y y y n
y
as-needed rest
2: y y y y y n
n
3: y y y y y n
n
4: y y y y y n
n
5: y y y y y n
n
6: y y y y y n
n
The above information is provided by AVAYA Inc. as a guide. See disclaimer on page 1
AAR DIGIT ANALYSIS TABLE
Total
Route
Call
Min
Max
Pattern
Type
7
7
2
aar
Pattern Number: 2
Inserted
Digits
Dgts
107
ITC BCIE Service/Feature BAND
rest
rest
rest
rest
rest
38
Page
1 of
2
Percent Full:
9
Node
ANI
Num
Reqd
1
n
Page
1 of
3
DCS/ IXC
QSIG
Intw
y
user
n
user
n
user
n
user
n
user
n
user
No. Numbering LAR
Dgts Format
Subaddress
unk-unk
none
none
none
none
none
none