IBM 3745 Series Service Functions page 98

Communication controller
Table of Contents

Advertisement

If there is no NCP answer, this screen is dis-
played.
The procedure is the same as in the previous
case.
13
1 Sc"EC'/'lELE"SE I
O,,'IP/lMl
I
3
~I:JE
CO',TROL
I
O/ALl STORE
I
DIAL T
B.CC~S
D/MT LSI<
O/AL T X'lEG
"CJRESS
CO~IPAREI
9
C"~-POI~T
TRACEI
19 O/IILT H?TSS/ESSI
NO RESPONSE FROM NCP
FI
:Uj~
F;>:'IENUI
F3:>IlAIl.~1
Mode Control
Figure
4-10.
Scanner Delayed Disconnect Screen
2
Scanner Mode Control Commands Details
START (ST)
Sent to the scanner to go from disconnected/stop mode to
disconnected/go mode.
CONNECT (CT) Sent to the NCP to make the scanner available to the NCP.
RESET (RT)
STOP (SP)
Put the scanner in reset mode, which allows using IML and
DUMP commands.
An unconditional disconnect command is sent to the NCP via a
mail box, then a stop command is sent to the scanner.
DELAYED DISCONNECT (OS) Sent to the NCP to request a conditional discon-
nection.
Table
4-1.
Commands AvailabilitY"According To MOSS State
Command
MOSS Alone
MOSS Offline
Dump
Yes
Yes
IML
Yes
Yes
Reset
Yes
Yes
Start
No
Yes
Stop
Yes
No
Table
4-2 (Page 1 of 2). Scanner Mode Control Commands
Current Mode
Possible Scanner Commands
Resulting Mode
CONNECTED
STOP
DISCTD-STOP
DISCONNECT
DISCTD-STOP
RESET
RESET
DUMP
RESET
IML
INITIALIZED
DISCTD-GO
STOP
DISCTD-STOP
RESET
RESET
DUMP
RESET
IML
INITIALIZED
DISCTD-STOP
START
DISCTD-GO
RESET
RESET
DUMP
RESET
IML
INITIALIZED
Chapter