CDF Messages
POWER SUPPLY OF CCU-A IS NOT OPERATIVE AND DISK READ ERROR
Cause: DUring a create, upgrade, or verify operation, the power supply of CCU-A becomes inOperative, and you get a disk read
error when reading the old CDF file.
Action:
Run the
pas
function to check the CCU power status, then If not successful, IML for disk checking.
POWER SUPPLY OF CCU-B IS NOT OPERATIVE
Cause: DUring a create, upgrade, or verify operation, the power supply of CCU-B becomes inoperative. The operation con-
tinues, but only on CCU-A.
Action: Check the power supply of CCU-B.
REFUSED BY CTl pGM: FAllBACK IN PROGRESS
Cause: The fallback was active dUring the last step of a hardware change.
Action:
Retry when you are
In
sWitchback.
STORAGE SIZE REQUEST FAilED FOR CCU-A
Cause: It was Impossible to obtain the storage size dUring a create, upgrade, or verify. The function has aborted.
Action:
Power-down then power-up PS 10 number 2 (CCU-A).
STORAGE SIZE REQUEST FAilED FOR CCU-A. CONTACT SERVICE REPRESENTATIVE
Cause:
It was Impossible to obtain the storage size dUring a create, upgrade, or verify. The function has aborted.
Action:
Power-down then power-up PS 10 number 2 (CCU-A). If the problem IS stili present run the CCU diagnostics.
STORAGE SIZE UNKNOWN FOR CCU A
Cause: The storage size IS unknown dUring a create, upgrade, or verify. The function has aborted.
Action:
Power-down then power-up PS 10 number 2 (CCU-A).
SWITCH CONFIGURATION REQUEST ERROR
Cause: The function aborted dUring a create, upgrade, or verify.
Action:
Power-down then power-up PS 10 number 2 (CCU-A).
SWITCH INITIALIZATION IN ERROR
Cause: An error occurred dUring a sWitch initialization.
Action:
Retry, then If not successful, Power-down then power-up PS ID number 2 (CCU-A).
THE FOllOWING MUX IS NOT FREE
Cause: The operator wants to add a MUX With EXTEND, and the follOWing MUX IS not free.
Action: Select a correct M UX.
THE MOSS IS ALONE, YOU CANNOT BEGIN THE HARDWARE CHANGE
Cause: The operator tried to start a hardware change but MOSS IS not online.
Action:
Run the upgrade.
THE MOSS IS OFFLINE, YOU CANNOT BEGIN THE HARDWARE CHANGE
Cause: The operator tried to start a hardware change but MOSS IS not online.
Action:
Run the MaN function (menu 2) or IPL phase 4 to get MOSS online.
THIS CA HAS NOT BEEN DISCONNECTED
Cause: The CA has not been disconnected before starting the hardware change.
Action:
Disconnect the CA.
THIS CA HAS NOT BEEN REMOVED FROM ASC CHAIN
Cause: The operator started a hardware change. The CA IS disconnected, but not removed from the ASC chain.
Action:
Remove the CA from the ASC chain by uSing CACM.
THIS CA HAS NOT BEEN REMOVED FROM CSGC CHAIN
Cause: The operator started a hardware change. The CA IS disconnected, removed from the ASC chain, but not from the CSGC
chain.
Action:
Remove the CA from the CSGC chain by uSing CACM.
Refer to the 3745 Advanced Operations Guide, SA33-0097, for explanation of the following messages
which are common to customers and CEo
• ADAPTER CONFIG STATUS IS INVALID
• BOX OPERATING CHANGE SUCCESSFUL
• CHANGE REJECTED: A FALLBACK IS ACTIVE
• DATA MARKED WITH
??
IS NOT AVAILABLE. CONTACT SERVICE REPRESENTATIVE
• DISK ERROR DURING WRITING PROCESS
• ERROR DURING CALL ACCESS FUNCTION