MSA (IPL Information)
FALLBACK COMPLETE
+
ERRORS: The fallback is complete although an error
has occurred. The 3745 should run normally.
FALLBACK IN PROGRESS The fallback operation is in progress.
IPL CANCELLED The 3745 initialization is cancelled by:
• The operator (immediate terminate function).
• Operator console power-OFF when the IPL was requested
from the console.
• The operator console switching from normal mode to test
mode.
• Automatic MOSS re-IML during a CCU/scanner step-by-
step IPL, or
• Two automatic MOSS re-IMLs during a CCU/scanner IPL.
IPL CHECK Fxx The IPL ends abnormally. The check code (Fxx) is also dis-
played on the hex display of the control panel.
IPL CHECK F1B CLOP ABEND xxxx The IPL ends abnormally. xxxx is the
hexadecimal CLOP abend code (refer to the "IMLlIPL" chapter
of the Maintenance Information Reference Manual, SY33-2056,
for the list of abend codes).
IPL COMPLETE The IPL is successfully completed.
IPL COMPLETE
+
ERRORS The IPL is complete, although an error has
occurred. Alarm 01 is displayed. The 3745 runs with some
restrictions.
IPL FROM MOSS DISK IN PROGRESS The IPL from the MOSS disk is in
progress.
IPL IN PROGRESS The IPL operation is in progress. The progression of the IPL
is indicated in MSA field F which displays the control program
storage addresses.
LINK IPL DETECTED ON L xxxx The control program loading/dumping is started
on a link-attached 3745.
LINK TEST PROGRAM ABEND A hardware error occurred at phase 3, while
loading the stand-alone link test.
LINK TEST PROGRAM LOADED The link test program is loaded.
LOAD IN PROGRESS ON CA xx The control program is being loaded on a
channel-attached 3745. The progression of the load is indi-
cated in MSA field F where the CCU storage addresses are dis-
played. x is the channel adapter number.
LOAD IN PROGRESS ON L xxxx The control program is being loaded on a link-
attached 3745. The progression of the load is indicated in MSA
field F where the CCU storage addresses are displayed. xxxx
is the decimal telecommunication line address.
RPO DETECTED ON L xxxx The remote power OFF (RPO) command is detected
on telecommunication line xxxx. xxxx is the decimal telecom-
munication line address.
Chapter 1. How to Use the MOSS Function Screens