TSS Messages
SCROLL IGNORED
Cause: You either requested a scroll forward and the displayed data IS at the end of the storage, or you requested a scroll
backward and the displayed data IS at the top of the storage.
Action:
None.
SELECT A SCANNER
Cause: You selected a TSS function without having selected a scanner.
Action: Select a scanner.
SELECTED SCANNER IS NOT A HPTSS: REQUEST IGNORED
Cause: You selected a TSS function reserved to H PTSS and the selected scanner IS a TSS.
Action:
Release the scanner and select an H PTSS.
SPECIFY A DELAYED ALTER
Cause: You requested an address compare function with action start delayed alter, but did not specify the delayed alter opera-
tlon.
Action:
Specify the delayed alter operation and resume address compare.
SPECIFY A DELAYED DISPLAY
Cause: You requested an address compare function with action start delayed display, but did not specify the delayed display
operation.
Action:
Specify the delayed display operation and resume address compare.
TO ALTER DATA, SPECIFY AN IMMEDIATE DISPLAY
Cause: You selected a display alter function. If you want to alter data, you must first display It.
Action:
None.
TO DELAY ALTER, ENTER NEW DATA, CHANGE I TO 0, PRESS SEND
Cause: You selected the alter subfunctlon.
Action: As requested by the message.
UNKNOWN NCP COMPLETION CODE
Cause: The control program returned an unknown completion code after a mailbox was sent by the MOSS.
Action: Terminate the function
UNEXPECTED SCANNER INTERRUPT: PRESS SEND TO RETRY
Cause:
MOSS received a scanner Interrupt on a command where no Interrupt IS expected. A BER Type 01, 1005 IS created.
Action:
Retry the command.
WARNING: LlC NOT ENABLED, DATA MAY BE ERRONEOUS
Cause: You want to display a control block (RAMA, RAMB, RAMC, ICF, LlC, FPS, FLR, or LHR) when the LlC IS In disable status
(no line active).
Action:
None.
XX BYTES ALTERED
Cause: You specified an Immediate alter operation In scanner/control storage, control blocks, local storage, or external regis-