TRSS Messages
INVALID INPUT
Cause: The entered Input IS invalid.
Action:
Enter a valid input.
INVALID INPUT: RE-ENTER FIELDS IN ERROR
Cause:
An Input field IS In error dUring alter.
Action:
Correct the field.
INVALID INTERRUPT RECEIVED FROM TRA: FUNCTION CANCELLED
Cause: An Interrupt was expected as the result of an M IOH but the expected Interrupt bit was found to be ON In the TCB
(should have been reset by MOSS level 4).
Action:
Run diagnostics.
INVALID NUMBER OF HALFWORDS: RANGE IS 1-48
Cause:
The requested amount of halfwords to display was out of range.
Action:
Enter a valid number of halfwords.
INVALID F KEY
Cause:
Self-explanatory.
Action:
Use a valid F key.
IOC/TRA ERROR: DUMP MAY BE INCOMPLETE
Cause:
According to the function being processed, an MIOH error occurred dUring an MIOH processing.
Action:
Retry, and If not successful, run the diagnostics.
IOC/TRA ERROR: FUNCTION NOT PERFORMED
Cause:
According to the function being processed, an MIOH error occurred dUring an MIOH processing.
Action:
Retry, and If not successful, run the diagnostics.
IOC/TRA ERROR: MODE NOW UNKNOWN
Cause:
According to the function being processed, an MIOH error occurred dUring an MIOH processing.
Action:
Retry, and If not successful, run the diagnostics.
IOC/TRA ERROR: NOT CONNECTED
Cause:
According to the function being processed, an MIOH error occurred dUring an ty110H processing.
Action:
Retry, and If not successful, run the diagnostics.
'
IOC/TRA ERROR: TIC MODE NOT REPORTED
Cause:
According to the function being processed, an MIOH error occurred dUring an MIOH processing.
Action:
Retry, and If not successful, run the diagnostics.
IOC/TRA ERROR: TRA INTERRUPTS NOT ENABLED
Cause: According to the function being processed, an MIOH error occurred dUring an MIOH processing.
Action:
Retry, and If not successful, run the diagnostics.
MOSS/TIC ERROR: FUNCTION CANCELLED
Cause: An Interrupt was not answered to MOSS dUring the disconnect process.
Action:
Run diagnostics.
NCP/MOSS ERROR: FUNCTION CANCELLED
Cause: A MOSS Interface table (MIT) was not found for the selected TIC. Since the NCP IS needed, the current function IS
cancelled.
Action: Verify NCP generation.
NCP/MOSS ERROR: PRESS SEND TO CONTINUE
Cause: A MOSS Interface table (MIT) was not found for the selected TIC. The NCP IS set not supporting TRSS. The function
continues after SEND IS pressed.
Action: Verify NCP generation.
NCP TRS SUPPORT NOT AVAILABLE: FUNCTION IGNORED
Cause:
NCP generation does not support TRSS.
Action:
None.
NO ACKNOWLEDGE FROM TRA: MODE NOW UNKNOWN
Cause:
The TRM did not respond with an Interrupt to MOSS dUring the disconnect process.
Action:
Run diagnostics.
5-18
3745 Communication Controller