IBM 3745 Series Service Functions page 28

Communication controller
Table of Contents

Advertisement

MSA (Scanner Information)
MSA Field Definition (Scanner Information)
Field N
CUSTOMER 10:
3745-xl0
SERIAL NUI·1BER:
CCU-A
PROCESS MOSS OFFLINE
RUN
BYP-IOC-CHK STOP-CCU-CHK
SCANNER 3 INITIALIZED
------------------------------------------------------------- mm/dd/yy 10:20
FUNCTION ON SCREEN: TSS SERVICES
FUNCTION PENDING:
Figure
1-10. MSA Example with TSS Information
Scanner information is displayed on line 4 for CCU-A, and on line 7 for CCU-B.
CUSTOMER 10:
3745
SERIAL l' I UI·1BER:
CCU-A
PROCESS MOSS OFFLINE
RUN
BYP-IOC-CHK STOP-CCU-CHK
SCANNER 3 INITIALIZED
[=:=J
L - [ _
_
_
--' I
[---J
i~
~
~
Figure
1-11. Fields of the TSS Information in the MSA
This figure shows the breakdown of the scanner information fields in line 4
(CCU A scanners) or 7 (CCU B scanners).
Information on the selected scanner:
• NO SCANNER SELECTED: You selected a scanner function before selecting
a scanner.
• SCANNER XX yyyyyyyyyyyy: Where xx is the number of the selected
scanner (1 to 32), and yyyyyyyyyyyy is any of the following:
CONNECTED The scanner is operational and under control of the CCU
control program.
DISCTD-GO
Disconnected-go: You entered the GO command while in the
DISCTD/STOP status. The scanner remains disconnected but
control code execution continues.
DISCTD-STOP Disconnected-stop: The control code is no longer under
control of the CCU control program, either after a STOP
command or after a scanner address compare hit.
INITIALIZED
The control code is loaded and the front-end adapter is oper-
ational.
INOPERATIVE The scanner is inoperative, or the CCU is not in RUN status.
RESET
You entered the RESET command, and you may initiate an
IML or a DUMP.
UNKNOWN-MODE The scanner is selected but it is impossible to identify its
status.
Chapter 1. How to Use the MOSS Function Screens
1-15