6. TEST
OPERATIONS
(TEST
MODE)
/MELSEC
(4)
Servo program stop
Pressing the [
t
] key stops the servo program currently being
executed; the axis decelerates and stops.
(a) Deceleration processing is executed based on the decelera-
tion time set in the parameter block currently used.
(b) Pressing the [
t
] key during deceleration has no effect.
(5)
Registered start setting
To execute the registered start again, change the display to the
Registered Start Setting screen by pressing the [DEL] key.
(a) When restarting the servo programs which were set during
the previous program number setting operation, press the
[DEL] and [BS] keys without registering any programs.
[Miscellaneous Function Operation]
(1)
Displaying a designated servo program
The designated servo program can be displayed
on
the
Registered Setting Start screen with the following procedure.
a) Move the cursor to the required servo program number by
pressing the [Arrow key].
displayed on the right side of the display.
b) Press the [FlO] key and the program next to the cursor is
c) Press the [FlO] key again
to return the display to the pre-
vious screen.
(2)
Displaying a servo program during sequential start execution
When the servo programs are executed with the sequential start
method, the next servo program can be displayed with the follow-
ing procedure.
a) Press the
[Fl
01 key when program execution stops. The next
servo program is displayed on the right side of the screen.
b) Press the [FlO]
key again to return the display to the pre-
vious screen.