Mitsubishi MELSEC-A A6MD Operating Manual page 57

Monitor display unit of programmable controller
Table of Contents

Advertisement

6. TEST
OPERATIONS
(TEST
MODE)
/MELSEC
1
Operation
[[MPG Operation
screen]]
MPG
Axis No.
4
selection
_ _ _ -
(1) MPG
(2)
Axis
(3) Pulse multiplication ratio seffchange
selection
setting
I
[MPG operation
of designated
(4) MPG opera- (5) MPG operation
1
tion
enabled
execution
I
. .
[Operation]
(1)
MPG selection
(a) Select and set the MPG to be used from those connected
to
A70SF terminals P1 to P3.
The set MPG is highlighted.
1) [ e ] : MPG connected to A70SF terminal P1
2) [
t
1: MPG connected to A70SF terminal P2
3) [-I: MPG connected to A70SF terminal P3
(2)
Axis setting
(a) Set the axis to be operated by the MPG.
(3)
Setting pulse multiplication ratio
(a)
To
set the pulse multiplication ratio, display the Pulse Multi-
plication Ratio Setting screen by pressing the [BS] key.
(b) Setting range:
1
to
100
(c) The MPG Monitor Operation screen is displayed when the
required pulse multiplication ratio is set.
[ l t o 1001
+
[CR]
(4)
MPG operation enable
(a) Press the [ J. ] key and the set data is written to the A73CPU.
If no data is set, '1' is written.
1) Axis number
2) Pulse multiplication ratio
(b) To change the MPG, axis and/or pulse multiplication ratio,
return the [PLS. GEN. PERMIT [ J. I ] key to the normal display
by pressing the [ J. ] key and change the setting.
After setting the required values, press the
[ J. ] key to write
the setting
to
the A73CPU data area.
(5)
MPG operation execution
MPG operation is possible with the designated
MPG when the
PLS. GEN. PERMIT display is highlighted.