9. SETTING LIMIT SWITCH OUTPUT DATA
/MELSEC
(2)
Point address sort and write
(a) The
[SI
key is used to sort point addresses.
1) The addresses set in the ADDRESS column are sorted from
2) If an address is equal to the
MAX or MIN value,
it
is deleted
the smallest value to the largest value.
before sorting is executed.
If the same address is used repeatedly, it is regarded
as
the same point. All repeatedly designated addresses ex-
cept one will be deleted.
(b)
The sorted point addresses are stored
in the A73CPU memory
as the point addresses for setting the limit switch
ON/OFF
pattern.
(3)
Setting limit switch ON/OFF pattern
(a) Press the [FlO] key and the limit switch ON/OFF pattern can
be set in the table displayed on the screen.
Each point (LY [ I [
1)
should be set.
(b)
An ON/OFF pattern can be set for up to eight points per axis.
(c) Use the following keys to set the ON/OFF pattern.
[N]: ON pattern
[F]: OFF pattern
1) When the [N] or [F] key is pressed, the cursor moves
the next point.
to
2)
If the [N] or [F] key is pressed when the cursor reaches the
MAX position, the cursor moves to the MIN position in the
next line without setting the ON/OFF pattern.
3)
Use an [Arrow]
key to move the cursor to the required
position.
9 - 5
IB
INAI 66235-A