17. Place a washer (6.2×0.5×17, S/Na) on shaft "A."
18. Place a leaf spring on shaft "A." The convex side of the spring should
face the frame. (See Figure 4-102.)
Figure 4-102. Installing the Leaf Spring
19. Place a washer (6.2×0.15×17, S/Na) on shaft "A." (See Figure 4-102.)
20. Place the ASF cam on shaft "A." (See Figure 4-103.)
Leaf Spring
Shaft "A"
Washers
Combination Gear
(18.144, 24)
Figure 4-103. Installing the ASF Cam
21. Remove the positioning pin from combination gear (18.144, 24). (See
Figure 4-103.)
22. Connect the torsion spring (3.92) to the ASF stopper lever. Hang the
short leg on the ASF stopper lever hook. (See Figure 4-104.)
ASF Stopper Lever
Hook
Torsion Spring (3.92)
Figure 4-104. Installing the Torsion Spring (3.92)