Drive paths
Use the following syntax to identify the drive paths:
Logical drive
//NC/MPF.DIR/XY.DIR/TEST.MPF
/card/user/sinumerik/data
//TCU/<tcu name>/X203
//TCU/mytcu/X203,1
//ACTTCU/FRONT,1
//ef3307/MPF.DIR/xy.DIR/TEST.MPF
//ef3307/MPF.DIR
//NC/ACT.DIR
//PLC/0800001P
Note
You must restart HMI sl in order to incorporate new entries and changes.
Exemplary structure of the ini file
Standard configuration
● The standard softkey is in the position HSK 3 (position 3 on the horizontal softkey bar).
● The softkey text is called "USB." Text is read from the text file.
● The icon sk_usb_front.png is displayed.
● The softkey is visible starting from access level 7 in the program manager.
[CONNECTIONS]
ConnectionNum=1
; local USB device of the current TCU
Connection1=//ACTTCU/FRONT,1
SK_Connection1=SL_PM_SK_LOCAL_TCU_USB
SoftkeyIndex1=3
SoftkeyTextContext1=SlPmLogicalDrives
SoftkeyTextFile1=slpmdialog
SoftkeyPicture1=sk_usb_front.png
AccessProgram1=7
AccessMachine1=7
AccessServices1=7
HMI sl (IM9)
Commissioning Manual, 07/2007, 6FC5397-1DP10-2BA0
Creating drive connections
Description
Current NC
Local drive on the CompactFlash card
(Linux)
Global TCU-USB drive
Global TCU-USB drive with partition
specification (default: 1st partition)
Local TCU-USB drive with partition
specification
External network drives (WinXP)
Network drive
//networkname/myshare
8.3 File "logdrive.ini"