Creating drive connections
8.1
Introduction
Set up connections
Up to 8 connections to logical drives (data carriers) can be configured in HMI sl. These
drives can be accessed via softkeys in the "Program manager" operating area.
The following logical drives can be set up:
● USB data carrier
● Network drives, option necessary: Network drive management
● CF card on the NCU, option necessary: 256 MB user memory on CF card
The dialog box is available from the "User" access level.
Note
It is not possible to configure NCU or PCU interfaces.
8.2
Setting up drives
You can define logical drives in the "Set up drives" window.
A user interface for configuration purposes is available in the Startup/HMI area. The
configuration data created from this is stored in the "logdrive.ini" file.
The file is stored on the CF card under the following path:
/user/sinumerik/hmi/cfg/logdrive.ini
USB local/USB global
If you configure a "USB local" type of connection, you will only have access via the TCU to
which the USB memory medium is connected.
With the "USB global" type of connection, you have access to the USB memory medium via
all TCUs located on the system network.
HMI sl (IM9)
Commissioning Manual, 07/2007, 6FC5397-1DP10-2BA0
8
59