7. To restore user data only, enter the following command:
Scenario II: Start the Command Shell with WinSCP on the PG:
1. Start WinSCP and enter the following data in the log-on window:
2. Select in the menu "Commands" → "Open Terminal".
3. To restore the data, enter the corresponding commands as described under steps 3 to 5
See also
● Connect (Page 27)
NCU Operating System (IM7)
Commissioning Manual, 07/2007, 6FC5397-1DP10-2BA0
sc restore –user backup01
Result: The user data are written back again.
All subsystems are then restarted:
sc start all
Result:
The system state stored in the file "backup01" is restored on the NCU.
– IP address of the NCU (or, if required, host name)
– User name "manufact" with password "SUNRISE".