Configuring alarms
10.1 Creating alarm texts
Insert parameter texts
1. Open the file "oem_indexparams_deu.ts" in the editor
2. In the tag <name>, enter an in-house name, e.g.
3. For each parameter text, a separate area must be inserted between the tags <message>
and </message>, e.g.
4. The <source> tag contains the parameter value (acc. to the scheme "1" or "2").
5. The <translation> tag contains the parameter text.
Create foreign-language parameter file and translate parameter texts
1. Copy the file you have just modified.
2. Change the language abbreviation in the file name, see "Supported languages" table, e.g.
"namexyz_eng.ts".
3. Create the file in the same /OEM/sinumerik/hmi/lng/ or /User/sinumerik/hmi/lng/ folder.
4. Open the file in the editor.
5. Enter the translated parameter text in the <translation> tag.
Complete configuration file
So that the newly-created parameter file is recognized in the text library of the "Alarm&Event
Service," the following names must be included in the configuration of the "Alarm&Event
Service":
● Identifer
● Basename (file name of the just-created parameter text files without language
● ContextName