Configuring alarms
10.2 Adapting the alarm log
4. You adapt the filter for the entry type in the <Filter> tag. Please observe the following:
Filter properties
A filter consists of the following three elements:
● <Identifier> <Relation> <Value>
The following entries are possible for "<Identifier>":
Entry
AlarmID
SourceID:
SourceURL:
<Attribute name>:
The following entries are possible for "<Relation>":
Entry
EQUAL
NOT
LOWER
HIGHER
The following entries are possible for "<Value>":
Numbers
Character
strings
100
– An alarm event is only entered in the log when it satisfies the filter criterion.
– If several filters are specified in succession, they must be logically ORed.
– Several filters must be combined in series with the keyword AND for an AND
operation.
Description
Alarm number
See Table Range of alarms (Page 90)
Arbitrary alarm attribute from the "slaedatabase.xml" file, such as "SEVERITY" or
"CLEARINFO".
Description
Equal to
Not equal to
Less than
Greater than
Commissioning Manual, 07/2007, 6FC5397-1DP10-2BA0
HMI sl (IM9)