Creating drive connections
8.2 Setting up drives
The following settings are made when configuring a logical drive:
General settings
The following settings apply to all types of connection.
● Protection level
● Softkey texts
Specific settings
The following settings will need to be made in accordance with the type of connection:
● No drive
● USB local (TCU that is currently selected)
● USB global (TCU)
60
The access rights for the connections can be set from level "Keyswitch 0" up to "Vendor".
If nothing is entered here, the default setting, "Keyswitch 0", will apply.
The assigned protection level applies to all operating areas.
Two lines are available for labeling softkeys in the "Program manager" operating area.
%n is accepted as a line separator.
If the first line is too long, it is wrapped automatically. If there is a blank, it is used as a
line separator.
No drive is specified for this connection, and no other fields are displayed.
– Connection
Enter the port to which the USB memory medium is connected on the TCU:
- Front (front of the operator panel)
- X203 (rear of the operator panel)
- X204 (rear of the operator panel)
– Partition
If required, enter the number of the partition on the USB memory medium here, e.g. 2.
If a USB hub is being used at the USB port, enter the USB port that is accommodating
this hub.
– Path
Enter the required start folder of the memory medium here.
– Device
Enter the name of the TCU to which the USB storage device is connected here, e.g.
tcu1. The NCU must already know the TCU name.
The remaining settings are the same as in the "USB local" section.