Protection levels
4.2 Setting protection level via machine data display
$MM_USER_CLASS_WRITE_WPFRAME=7
Description:
Range of values: 0 - 7
Default:
Effective:
$MM_USER_CLASS_WRITE_USER_FRAME =7
Description:
Range of values: 0 - 7
Default:
Effective:
$MM_USER_CLASS_WRITE_FRAMES_FINE =7
Description:
Range of values: 0 - 7
Default:
Effective:
$MM_WRITE_FRAMES_FINE_LIMIT =7
Description:
Range of values: 0 - 7
Default:
Effective:
USER_CLASS_WRITE_PROGRAM=7
Description:
Range of values: 0 - 7
Default:
Effective:
USER_CLASS_TEACH_IN=7
Description:
Range of values: 0 - 7
Default:
Effective:
30
Write protection for frame workpiece reference point
7
Restart
Write protection for user frames (settable ZO)
7
Restart
Write protection for all ZOs fine
7
Restart
Input limit for all ZOs fine
7
Restart
Protection level for editing a part program
7
Restart
Protection level for writing a program
7
Restart
Commissioning Manual, 07/2007, 6FC5397-1DP10-2BA0
HMI sl (IM9)