Siemens SINAMICS S120 Function Manual page 318

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic functions
7.2 Reference parameters/scaling
Scaling for the S_INF drive object
Table 7- 4
Size
Reference frequency
Reference voltage
Reference current
Reference power
Reference modulation
depth
Reference temperature
Reference electrical
angle
Scaling for the B_INF drive object
Table 7- 5
Size
Reference frequency
Reference voltage
Reference current
Reference power
Reference temperature
Reference electrical
angle
318
Scaling for the S_INF drive object
Scaling parameter
100% = p2000
100% = p2001
100% = p2002
100% = r2004
100% = Maximum output
voltage without overload
100 % = p2006
100 % = p2005
Scaling for the B_INF drive object
Scaling parameter
100% = p2000
100% = p2001
100% = p2002
100% = r2004
100 % = p2006
100 % = p2005
Default when commissioning for the first time
p2000 = 50 Hz
p2001 = p0210
p2002 = r0206/p0210/√3
r2004 = r0206
-
100°C
90°
Default when commissioning for the first time
p2000 = 50 Hz
p2001 = p0210
p2002 = r0206/p0210/√3
r2004 = r0206
100°C
90°
Function Manual, 11/2017, 6SL3097-4AB00-0BP5