Siemens SINAMICS S120 Function Manual page 155

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Determined data
r1951 voltage emulation error, current val-
ues
Note regarding r1950 to p1953:
Active when the function module "extended torque control" is activated and activated compensation
of the voltage emulation error (p1780.8 = 1).
r1973 encoder pulse number identified
Note:
The encoder pulse number is only determined with a very high degree of inaccuracy (p0407/p0408)
and is only suitable for making rough checks. The sign is negative if inversion is required (p0410.0).
r1984 pole position identification angular
difference
Note:
r1984 indicates the difference of the commutation angle offset before being transferred into p0431.
-
Note:
If the encoder inversion is changed using motor data identification, fault F07993 is output, which
refers to a possible change in the direction of rotation and can only be acknowledged by p1910 = -2.
Table 4- 15
Determined data
r1934 q inductance identified
r1935 q inductance identification current
Note:
The q inductance characteristic can be used as basis to manually determine the data for the current
controller adaptation (p0391, p0392 and p0393).
r1937 torque constant identified
r1938 voltage constant identified
r1939 reluctance torque constant identified
r1947 optimum load angle identified
r1969 moment of inertia identified
r1973 encoder pulse number identified
Note:
The encoder pulse number is only determined with a very high degree of inaccuracy (p0407/p0408)
and is only suitable for making rough checks. The sign is negative if inversion is required (p0410.0).
r1984 pole position identification angular
difference
Note:
r1984 indicates the difference of the commutation angle offset before being transferred into p0431.
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Data determined using p1960 for synchronous motors (rotating measurement)
4.13 Motor data identification
Data that is accepted (p1910 = 1)
p1953 voltage emulation error, current offset
-
p0431 commutation angle offset
p0410 encoder inversion actual value
Data that is accepted (p1960 = 1)
-
-
p0316 motor torque constant
p0317 motor voltage constant
p0328 motor reluctance torque constant
p0327 optimum motor load angle
p0341 motor moment of inertia · p0342 ratio between
the total moment of inertia and that of the mo-
tor + p1498 load moment of inertia
-
p0431 commutation angle offset